一、產品簡介
遙控點火裝置控(kong)制箱主要應用于主要用于石油鉆井(jing)作業和天然氣勘探開發中(zhong)放噴可燃有(you)害(hai)氣體或廢(fei)氣(qi)的燃燒,以消除(chu)其(qi)對環(huan)境(jing)和安全的危害,是一種安全的環(huan)保設備。
遙控點火裝置控制箱主(zhu)要由控制箱、高(gao)壓連接線以及點火槍等幾部(bu)分組成。控制箱內置24VDC蓄(xu)電(dian)(dian)池,通過外接220VAC電(dian)(dian)源可對蓄(xu)電(dian)(dian)池充電(dian)(dian)。設置一(yi)組太陽能(neng)板也可(ke)以對蓄(xu)電池充電,點火設(she)備主要(yao)通過(guo)面板按鈕(niu)操(cao)作。該產品采用(yong)高性(xing)能的點(dian)火電路,性(xing)能穩定,工作可靠。
遙控點火裝置控制箱還專(zhuan)門設立了電(dian)(dian)池電(dian)(dian)壓(ya)實時監(jian)控電(dian)(dian)路(lu)、當電(dian)(dian)池電(dian)(dian)壓(ya)過低(di)時,操作面板上的欠壓(ya)燈亮并發出(chu)蜂鳴報(bao)警(jing),提醒用戶及時充電。
二、 遙控點火裝置技術參數
1、工作(zuo)電(dian)源:DC24V
2.外(wai)接充電(dian)電(dian)源;220V
3、環(huan)境溫度:-40~80℃
4、充(chong)電時(shi)間(jian):≥8h
5、蓄電池:24VDC 65Ah
6、手動(dong)點(dian)火:控制箱面板上所設手動(dong)按鍵(jian)操作,點(dian)火持續(xu)時間由時間繼電器控制(可設定)。
7、外形尺寸:1.7*米(高)*0.86米(長)*0.65米(寬)
8、高壓電纜:每根L=80m。
9、點(dian)火槍(qiang):(長度(du)和(he)外形尺寸可(ke)根據用戶要求(qiu)訂(ding)做)
L=1000+115mm,前端耐溫1300℃
三、遙(yao)控點火裝置技術要(yao)求
遙控點(dian)火裝置總體(ti)性能是由(you)1臺獨立(li)的控制箱(xiang)組成,控制箱內部獨立控制一臺點火(huo)器。可(ke)分別(bie)通(tong)過手動/遙(yao)控控(kong)制一路輸氣管線頭部的點火。現場可根據(ju)實際需(xu)要選擇使(shi)用,其每臺控(kong)制箱的(de)點火裝置具體要求如(ru)下;
1、點火裝置應能點燃(ran)氣(qi)鉆修井過程(cheng)中液氣(qi)分離(li)器(qi)分離(li)出(chu)的(de)氣(qi)體(ti)或放(fang)噴管(guan)線(xian)排出(chu)的(de)游離(li)氣(qi)體(ti)。
2、點火裝(zhuang)置應(ying)全天候工作。
3、裝(zhuang)置太陽能供電電源為(wei)一組/臺(tai)獨立的供電電源,電源可單獨(du)或同(tong)時供電給(gei)點火控制部分(fen)。應采用(yong)24V可充電(dian)(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)(dian)池(chi)作(zuo)為(wei)安全電(dian)(dian)(dian)(dian)(dian)源,并帶有(you)太(tai)陽(yang)(yang)能(neng)自動充電(dian)(dian)(dian)(dian)(dian)裝置,太(tai)陽(yang)(yang)能(neng)充放電(dian)(dian)(dian)(dian)(dian)控(kong)制器需放置在主電(dian)(dian)(dian)(dian)(dian)控(kong)箱(xiang)內(nei)部。在雨(yu)、雪(xue)、霧天(tian)等不利于太(tai)陽(yang)(yang)能(neng)使用(yong)的(de)情況(kuang)下,現場可使用(yong)24V恒(heng)壓電(dian)(dian)(dian)(dian)(dian)源,接入主控(kong)箱(xiang)電(dian)(dian)(dian)(dian)(dian)源插口工作(zuo),恒(heng)壓電(dian)(dian)(dian)(dian)(dian)源為(wei)一個(DC24V,500W)需放置在主電(dian)控箱內部。
4、每臺控(kong)制柜點火輸(shu)出控(kong)制為一個控制對(dui)象。
5、點火裝置(zhi)控制系(xi)統應顯示電池電壓參數,配置(zhi)電源欠壓指(zhi)示燈(deng),在操(cao)作(zuo)面板上(shang)有電(dian)(dian)壓表(biao)和電(dian)(dian)流表(biao)各一塊。顯(xian)示(shi)電池的電壓電流情況(kuang)。
6、每個點火點(控制對象)的引火燃氣(qi)應獨(du)立
7、控制(zhi)箱內,點火器(qi)能夠獨立(li)可拆卸
8、氣路與(yu)電路的(de)啟(qi)動采用同一個(ge)按鈕,同時啟(qi)動或停(ting)止(zhi)。
四、控制柜以及氣(qi)路(lu)的(de)具(ju)體(ti)技術參數
1、蓄電(dian)池: 24V DC ×65AH 免(mian)維護電池
2、太陽能板功率:1組×50W/臺(12V),外形尺寸:550*670mm
3、電 磁 閥(fa): D15, 安裝在控制柜(ju)內部(bu)。
4、高壓電(dian)纜: 鎧裝鐵(tie)氟(fu)龍, ?2.5mm×80m 防(fang)護≤200℃
5、恒壓電源: 24V DC 500W
6、導(dao)電(dian)(dian)桿/電(dian)(dian)嘴: ≥2500V脈沖,溫耐≤1200℃,電(dian)(dian)火花能量(liang)20焦耳(er)